MIL-P-80114D
3.14 Marking on instruments, control panels, charts, and plates. All
words on the machine including all Instruments, control panels, control units,
charts, plates, and related attachments shall be in the English language.
contrasting
in boldface on a
Characters shall be permanently marked
background. All plates shall be corrosion resistant.
3.14.1 Lubrication plate or chart. When specified (see 6.2), a lubri-
cation plate or chart shall be attached to each press. If a chart is
furnished, it shall be placed in a transparent plastic folder, or permanently
sealed between clear plastic sheets. Unless otherwise specified (see 6.2),
the information provided on the chart or plate shall be as listed below:
Points of lubricant application
Type of lubricant
Servicing interval
Military or Federal specification for each lubricant,
(if applicable)
3.14.2 Nameplate. A nameplate shall be securely attached to each press.
Unless otherwise specified (see 6.2), the nameplate shall contain the
information listed below:
Nomenclature
Manufacturer's name
Manufacturer's model designation
Manufacturer's serial number
Power input (volts, total amps, phase, frequency)
Amp rating of largest motor
Short circuit/over-current protection rating
Contract number or order number
National stock number or plant equipment code
Date of manufacture
3.14.3 Hydraulic fluid requirements plate. When specified (see 6.2), a
hydraulic fluid requirements plate shall be attached to the machine at the
hydraulic reservoir fill point. Unless otherwise specified (see 6.2), the
plate shall contain the following information:
Type of fluid (SAE number or military or Federal
specification number)
Type of filter
and its accessories shall
Workmanship of the press
3.15 Workmanshi
meet all requirements specified herein.
4.
QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise specified in the
contract or purchase order, th e contractor is responsible for the performance
of all inspection requirements (examinations and tests) as specified herein.
Except as otherwise specified in the contract or purchase order, the
contractor may use his own or any other facilities suitable for the
herein,
unless
requirements
specified
the inspection
performance of